Product Introduction:

The SIC-7 flue gas analyzer (deuterium lamp) is a gas analysis product developed by the company based on the ultra clean emission conditions of coal-fired power plants and years of accumulation of ultraviolet absorption spectroscopy technology. It is a multiple return light path gas analysis product. This analyzer is based on ultraviolet differential absorption spectroscopy (DOAS) and chemometric algorithm (PLS), and can measure the concentrations of gases such as SO2, NO, NO2, O2, NH3, CO, CO2, Cl2, O3, H2S, HCl, CH3 I, CH2O, etc. Its various indicators meet or exceed those of similar products at home and abroad. At the same time, our company's flue gas analyzer is equipped with a self-developed infrared module to measure gases such as CO according to customer needs. Compared with electrochemical methods and other technologies, it has higher accuracy, faster response, and higher reliability, solving the problem of short electrochemical life.

Product Features:

Using ultraviolet differential absorption spectroscopy technology and chemometric algorithms to detect low detection limits and small temperature drift;

It can directly measure NO and NO2 to obtain NOx without the need for a NO2 to NO converter;

Not affected by factors such as particulate matter and moisture;

High reliability without optical moving parts, and on-site vibration has no impact on measurement;

Using a return light path and high-quality spectrometer, the minimum range can reach 0-20mg/m3, and the minimum detection limit is 0.01mg/m3.

Product Application:

Monitoring and process control of exhaust emissions from coal-fired power plants, waste to energy plants, cement plants, glass plants, lime plants, ceramic plants, sintering plants, coke ovens, desulfurization processes, denitrification processes, etc.

Product specifications:

Measurement techniques: UV DOAS (SO2, NOx), electrochemical (O2), infrared TDLAS (CO) Range: 0-50-100mg/m3 (SO2, NO, NO2) (lower range can be customized), 0-25% (O2), customizable (CO)

Preheating time: No preheating required
Relay output: 14 channels
Switch input: 6 channels
Analog output: 5 channels of 4-20mA output
Linear error: ≤± 1.5% F.SAnalog input: 3-channel 4-20mA input
Repeatability: ≤ 0.5%Digital communication: RS485/RS232/TCP
Zero drift: ≤± 2% F.S./7dProtection level: IP42
Range drift: ≤± 2% F.S./7dWorking temperature: -10 ℃~+40 ℃
response time:<30s(T90Working humidity: 0-95% RH


×