Product Detail

Dust PM online concentration detector

Collect
  • trade description

Execution standards:

       GB/T 3836.1-2021 Explosive Atmosphere Part 1: General Requirements

       GB/T 3836.2-2021 Explosive Atmosphere Part 2: Equipment Protected by Flameproof Enclosures "d"

       GB/T 3836.3-2021 Explosive Atmosphere Part 3: Equipment Protected by Increased Safety Type "e"

       GBT 3836.9-2021 Explosive Atmosphere Part 9: Equipment Protected by Sealed Type "m"

       GB/T 3836.31-2021 "Explosive Atmosphere Part 31: Equipment Protected by Dust Ignition Resistant Enclosures" t ""

       GB 3836.15-2000 "Electrical equipment for explosive gas atmospheres - Part 15: Electrical installations in hazardous areas (excluding coal mines)"

       GB 12476.1-2013 "Electrical equipment for use in environments with combustible dust - Part 1: General requirements"

       GB12358-2006 General Technical Requirements for Workplace Gas Detection and Alarm Devices

       GBZ 2.1-2007 Occupational Exposure Limits for Hazardous Factors in the Workplace

       GB 4208-2008 "Degrees of Protection Provided by Enclosures (IP Code)

Characteristics of dust concentration detector:

■ Customizable range intelligent sensor, using safety technology, supporting multi dust and multi range detection, with a range of selectable (100ug/m3~1000mg/m3), and can provide customized products according to user needs;

■ The use of MCU chips highlights the detector's low power consumption, safe and reliable performance, precise data conversion, stable signal output, and more; Multiple signal outputs such as 4-20mA, RS485, and switch values are convenient for connecting to industrial control systems such as PLC, DCS, and DDC. It can also be used to control equipment such as fans and solenoid valves through switch value linkage;

■ Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc;

■ Dot matrix high-definition LCD TFT display screen, with Chinese and English operation interfaces that can be switched by oneself;

■ The detector can be operated through remote control without opening the cover, including functions such as alarm value, zero adjustment, calibration, reset, and address code modification;

■ Local integrated sound and light alarm indication, which can achieve remote alarm prompts for mobile phones, computers, monitoring rooms, third-party platforms, etc. through alarm control ■ host or wireless signals. It can also be remotely controlled by infrared with one click silencing;

■ Aluminum alloy cast explosion-proof shell, sturdy and durable;

■ Through various international certifications such as CMA, CNAS, CE, ROHS, SIL, UL, ECM safety, etc.

■ Explosion proof certificate level: Ex db eb mb IIC T4 Gb; Ex mb tb IIIC T130℃ Db;

■ Explosion proof certificate number: SYEx23.0499;

■ Protection level: IP65;



Product parameters of dust concentration detector:

output signal

① 4-20mA signal: standard 12 bit precision 4-20mA output chip, transmission distance of 1km

② RS485 signal: using standard MODBUS RTU protocol, transmission distance of 1km

③ Voltage signal: 0.4-2V, 0-5V, 0-10V output, optional (choose between voltage output and current output -)

④ Switching signal: Standard configuration includes 1 set of passive contact relays with a capacity of 220VAC 3A/24VDC 3A

⑤ Wireless signals such as GPRS, 4G, WIFI, LORA, ZigBee, etc


receiverUser computer, control alarm, PLC, DCS, DDC, etc
way of workingDiffusion type
Testing mediumDust particles(PM1、PM2.5、PM10、TSP)
Detection PrincipleLaser scattering
detection rangeSmall range: 0-1000/2000/4000/6000/8000/9999ug/m3 Large range: 0-10/100/1000mg/m3 (range can be customized)
Resolution0.001、0.01、0.1、1(Depending on the measurement range)
detection error≤± 5% F.S (≤ 5% over full range)
Repeatability≤±2%
linearity error≤±2%
response time≤30S
working voltage DC24V(12V~30V)
operation temperature-20℃~50℃(special requirements:(-40℃~+70℃℃)
Working humidity10-95%RH(No condensation)
Sensor lifespan2-3 years (depending on the usage environment)
Explosion proof formThe probe transmitter and sensor are both explosion-proof。
Connecting cables

① Choose a three core shielded cable for 4-20mA and a four core cable for RS485. When the distance exceeds 1000 meters (with one detector), the single wire diameter should be greater than 1.5mm, and the shielding layer should be grounded.

② Wireless transmission: It can be equipped with built-in LORA and Zigbee modules for short-range wireless transmission; External GPRS/4G module for remote data transmission to cloud platform, allowing for viewing of historical records on both computer and mobile devices without distance limitations (optional)

Alarm methodOn site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software alarm, etc
Alarm settingsStandard configuration with two-level alarms; Alarm modes can be set: regular high and low alarm, interval control alarm
External dimensions252*205*93(L*W*H)
electrical interfaceDefault M20X1.5 internal thread, optional 3/4NPT, 1/2NPT
Measurement certificateOptional, customer pays for expenses
attachmentOne copy each of the packaging box, instruction manual, certificate of conformity, and delivery note
Optional accessories

Temperature and humidity measurement, 220V to 24V power adapter

Optional accessories

Computer monitoring accessories: free upper computer software, USB to RS485 conversion cable. If network transmission is required, an RS485 to Ethernet converter is also needed


Installation position of dust concentration detector:

1: Dust concentration measuring instrument, fixed, generally requires separate installation by design institutes;

2: The location for belt transportation should be installed between 0.5-2 meters above the transfer point;

3: Production workshop, install columns or walls about 2.5 meters in the workshop;

4: Install the polishing machine between 0.5-2 meters above the polishing machine in places with it;

5: The place where coal powder, flour, and other materials are stacked is called the production point, which is installed above the production point. For example, if the coal powder is 15 meters high, 

it should be installed 0.5-2 meters above this point, which is about 18 meters.


The range of the dust concentration detector refers to the regulations:

For questions related to the exposure limits and concentrations of various types of dust and their potential harm to human health, please consult sales personnel.

Allowable concentration of dust in workplace air


Serial NumberChinese nameEnglish name

化学文摘号(CASNO.)

PC-TWA(mg/m3)

total dustrespirable dust
1白云石粉尘Dolomite dust
8
4
2玻璃钢粉尘FRP dust
3-
3茶尘Tea dust
2-
4沉淀Si02(白炭黑)Precipitated silica dust112926-00-85-
5大理石粉尘Marble dust1317-65-38
4
6电焊烟尘Welding fume
4-
7二氧化钛粉尘Titanium dioxide dust13463-67-78-
8沸石粉尘Zeolite dust
5-
9酚醛树酯粉尘

Phenolic aldehyde resin dust


6-
10谷物粉尘(游离Si02含量<10%)Grain dust(free Si02<10%)
4-
11
硅灰石粉尘Wollastonite dust13983-17-05-
12
硅藻土粉尘(游离Si02含量<10%)Diatomite dust(freeSiO2<10%)61790-53-26-
13滑石粉尘(游离Si02含量<10%)Talc dust (free Si02<10%)14807-96-631
14活性炭粉尘Active carbon dust64365-11-3
5-
15聚丙烯粉尘Polypropylene dust
5-
16聚丙烯腈纤维粉尘Polyacrylonitrile fiber dust
2-
17聚氯乙烯粉尘Polyvinyl chloride (PVC)dust9002-86-25-
18聚乙烯粉尘Polyethylene dust9002-88-45-
19
铝尘

铝金属、铝合金粉尘

氧化铝粉尘

Aluminum dust:

Metal & alloys dustAluminium oxide dust

7429-90-5


3

4


-

-

20麻尘(游离Si02含量<10%)

亚麻

黄麻

苎麻

Hemp dust(freeSiO2<10%)

Flax

Jute

Ramie



1.5

2

3


-

-

-

21煤尘(游离Si02含量<10%)Coal dust(free Si02<10%
42.5
22棉尘Cotton dust
1-
23木粉尘Wood dust
3-
24凝聚SiO2粉尘Condensed silica dust
1.50.5
25膨润土粉尘Bentonite dust1302-78-96-
26
皮毛粉尘Fur dust
8-
27人造玻璃质纤维

玻璃棉粉尘

矿渣棉粉尘

岩棉粉尘

Man-made vitreous fiber

Fibrous glass dust

Slag wool dust

Rock wool dust



3

3

3


-

-

-

28桑蚕丝尘Mulberry silk dust
8-

29

砂轮磨尘Grinding wheel dust
8-
30石膏粉尘Gypsum dust10101-41-484
31石灰石粉尘Limestone dust1317-65-384
32

石棉(石棉含量>10%)

粉尘

纤维

Asbestos(Asbestos>10%)

dust

Asbestos fibre

1332-21-4


0.8

0.8f/ml


-

-

33石墨粉尘Graphite dust7782-42-542
34水泥粉尘(游离Si02含量<10%)

Cement dust (free SiO2<10%)


41.5
35炭黑粉尘Carbon black dust1333-86-44-
36碳化硅粉尘Silicon carbide dust409-21-284
37
碳纤维粉尘Carbon fiber dust
3-

38

矽尘

10%≤游离SiO2含量≤50%

50%<游离SiO2含量≤80%

游离SiO2含量>80%

Silica dust

10%≤free SiO2≤50%

50%<free SiO2≤80%

free SiO2>80%

14808-60-7


1

0.7

0.5


0.7

0.3

0.2

39稀土粉尘(游离Si02含量<10%)

Rare earth dust(freeSi02<10%)


2.5-
40洗衣粉混合尘Detergent mixed dust
1-
41烟草尘Tobacco dust
2-
42萤石混合性粉尘Fluorspar mixed dust
10.7
43云母粉尘Mica dust12001-26-221.5
44珍珠岩粉尘Perlite dust93763-70-384
45蛭石粉尘Vermiculite dust
3-
46重晶石粉尘Barite dust7727-43-75-
47其他粉尘a

Particles not otherwise regulated


8-

a: Refers to dust with a free SiO2 content of less than 10%, free of asbestos and toxic substances, and without established allowable concentrations. All types of dust listed in the table (excluding asbestos fiber dust) with free SiO2 above 10% shall be treated according to the allowable concentration of silica dust.

For dust, use over limit multiples to control the excessive fluctuations in its short-term exposure level. Under the premise of complying with PC-TWA, the exceedance factor of dust is twice that of PC-TWA



×
seo seo